ARINC 818 to SDI Converter

iWave’s ARINC 818 to SDI Converter is a rugged, standalone module designed for seamless conversion between SDI/built-in test patterns and ARINC 818 formats accommodating various resolutions and refresh rates. The intuitive web-based GUI allows for easy remote configuration of the system, making it an ideal solution for complex video conversion needs in aerospace and defence environments.
  • Quick ARINC 818-2 ICD customization as per customer requirement.
  • ARINC 818 will support standard/custom resolution and frame rate up to 2k@60fps
CONTACT SALES

Documents

FeaturesDetails
Hardware Specs1 x SDI Video Input fixed as per standard SDI Resolutions.
1 x SDI Video Output fixed as per standard SDI Resolutions.
1 x DP Video Output up to 2K @ 60 fps.
1 x SFP Connector for ARINC 818 Optical or 75-ohm
Copper i/f for ARINC818 input and output channel.
2 x Ethernet interface for GUI Application & System Initial Configuration.
ARINC 818Line rate: FC 1x, 2x, 3x, 4x, 5x, 6x, 8x, and 10Gbps
Resolution: Standard/Custom resolutions up to 2k@60fps subjected to link rate.
Frame rate: 25, 30, 50, and 60 fps.
GUISystem Configuration like Link Rate, Resolution, fps, Video Source Selection and detailed Video Timings as per required ICD Configuration.
System Monitoring including ARINC Errors.
FunctionalitySDI to ARINC818 Conversion
Built-in test pattern to ARINC818 Conversion
ARINC818 to SDI conversion
ARINC818 to DP conversion
HighlightsHandles multiple resolutions and refresh rates up to UHD @30FPS or 2K @60FPS.
ARINC 818 to SDI and SDI to ARINC 818 Conversion supported.
Compatible with Linux OS for flexible deployment.
Supports ARINC 818 to DP Conversion
Contains in-built test patterns for transmission and validation.
Operating Temperature-20°C to +55°C
Size/Dimension109 mm x 109 mm x 41 mm
Power Input12V and 5A

img

Product Design Process

Our design process transforms your vision into reality with innovation, quality, and collaboration.

Learn More

img

Certification & Qualification

Ensuring Compliance, Quality, and Trust Through Certification & Qualification.

Learn More

img

Product Lifecycle Management

Ensuring Longevity, Reliability, and Seamless Product Evolution.

Learn More

img

Mechanical Services

Precision Engineering for Reliable, High-Performance Mechanical Solutions.

Learn More

FAQs

ARINC 818, also known as the Avionics Digital Video Bus (ADVB), is a standard for high-speed, low-latency, point-to-point video transmission in avionics systems. It carries uncompressed video, audio and data over a serial link, which is why it is widely used in cockpit displays, sensor video distribution and mission systems.

Unlike general-purpose video interfaces such as HDMI or DisplayPort, ARINC 818 is designed for avionics. It supports configurable Interface Control Documents (ICDs), so one standard can fit many different display and sensor requirements.

iWave offers ARINC 818 recorders, monitors, video conversion COTS products and analyzers. The portfolio also includes an ARINC 818-2 IP core that offers point-to-point, high-speed, low-latency video transmission and can be implemented on any transceiver-based FPGA device. Together these cover the full design-to-deploy cycle, from prototyping and integration to testing and fielding.

ARINC 818-3 is the later revision of the standard and adds features such as improved support for higher line rates and additional functionality. ARINC 818-2 remains the version most widely deployed today. iWave provides both ARINC 818-2 and ARINC 818-3 solutions for aerospace applications. You can choose the revision your platform requires.

The Interface Control Document (ICD) is the agreement between transmitter and receiver that defines how a given link behaves: resolution, frame rate, pixel format, link rate, how video is divided into containers and objects, and what ancillary data is carried. ARINC 818 is deliberately flexible, so two compliant devices will only interoperate if they are built to the same ICD. Most integration problems come from ICD mismatches, not protocol faults.

If the core goes into airborne electronic hardware that is subject to DO-254, you will need compliance evidence appropriate to the design assurance level (DAL) of the function. This is why many teams ask for IP delivered with certification support, such as requirements, verification results and traceability, rather than a bare netlist. Confirm what is included before choosing a core.

Yes. Besides video, an ARINC 818 link can carry ancillary data and custom data, such as timing, status, files or sensor metadata, within the same frame structure. Multiple video streams can also be multiplexed over a single link, depending on the ICD and available bandwidth.

video-thumbnail
youtube-play-icon
video-thumbnail
youtube-play-icon
video-thumbnail
youtube-play-icon
img

ULL Streamer in Surgery and Medical Imaging

Learn More
img

100G UDP IP Core for High-Speed FPGA Solutions

Learn More
img

NAND Host Controller for Space Applications

Learn More
img

ULL Streamer and Recorder for Remote Surgeries

Learn More
img

ARINC 818-2 SCC for Aircraft Cockpit Video Display

Learn More
img

ARINC818 Digital Video Recorder (DVR)

Learn More